Real-Time Power Load Display |
|
 |
FSTN Display for Wide Viewing Angles |
|
 |
Temperature Monitoring of Up To 4 Components |
|
 |
Fan RPM Monitoring & Control (3 x voltage, 1 x PWM) |
|
 |
Timer Display |
|
 |
Built-In Protection Circuit & Alarm |
|
|
|
|
 |
|
| Dimensions |
147(L) x 87(W) x 42(H) mm |
| Power & Temperature Display |
10~999W/ -9.9 ¡ÆC~+99.9 ¡ÆC |
| Fan Compatibility |
1 x 4-Pin(Supports fans with PWM function) |
| 3 x 3-Pin(Supports fans with RPM output function)
|
| Fan RPM Control |
PWM Regulation Method (Fan PWM) |
| Voltage Control Method (Fan No.1~3) |
| Output Current |
MAX 0.7A |
| Output Voltage |
+4~11VDC |
| Input Voltage |
+12VDC/+5VDC |
|
| |
 |
 |
|   |
 |
Power Load Meter: Displays Power Load between 10 ~ 999W.
Readings of 1 ~ 9W are shown as "Lo" and readings
of 1000W+ are shown as "Hi". |
|
 |
Timer: Timer shows Computer usage time and resets when
Computer is turned OFF. |
|
 |
RPM Display: RPM is displayed in units of 10RPM. Values
of 200RPM and below are shown as "0". Values
between 201 ~ 6000RPM are supported by the display. |
|
 |
Temperature Display: Displays temperatures between -9¡ÆC
and 99C. Temperatures below -10¡ÆC are shown as "Lo".
The Display will blink temperatures between 80 ~ 99.9¡ÆC
and display "Hi" for temperatures above 99.9¡ÆC. |
|
 |
Fan Channel Display. |
|
 |
Jog Wheel: Jog Wheel is used for adjusting Fan RPM and
selecting a Fan Channel. RPM can be set from 60 to 6000RPM
in units of 60RPM. |
|
|
|
| |
 |
 |
Standard Fans (Fan 1~3): 3-Pin fans that support the
RPM output function can be connected for use.
PWM Fan : A 4-Pin fan that supports the PWM function can
be connected for use. |
|
 |
Temperature Sensor: Four temperature sensors can be
connected. |
|
 |
CVS Terminal: Receives the measured values of the CVS.
|
|
 |
Power Connector: Connects with the PSU¡¯s 4-Pin connector.
|
|
|
|
| |
 |
 |
- One ZM-MFC3
- One CVS (Ampere/Voltage Sensor)
- One CVS Extension Bracket
- One Temperature Sensors
- One C3 Cable
- One Y Cable
- One 4-Pin Cable
- One 3-Pin Cable
- One Bracket Screw
- Four ZM-MFC3 Installation Screw
- One User¡¯s Manual |
|
|
|
| |
 |
| Zalman affixes a Computer Noise Prevention System (CNPS) mark to all components
used for noiseless computers. |
| |
 |
 |
Plugging in the CVS Cable of the CVS into the motherboard¡¯s USB
port may damage the motherboard and CVS. |
|
 |
If the current to be measured exceeds 10A (RMS), use a cable or
conductor that allows current greater than the current to be measured
to flow through it, and always connect protective grounding prior
to use of this instrument. |
|